Solutions
/
GMP Biomanufacturing
/
Downstream Processing

Downstream bioprocessing software for capture, polish, and viral clearance

Protein A capture, polishing chromatography, viral inactivation and filtration, UF/DF, and bulk fill, with resin lifecycle and filter integrity bound to the batch.

THE PROBLEM

Where legacy LIMS break down

Downstream is where a batch becomes a product, and every step has a parameter window that has to hold. Low pH viral inactivation needs a minimum hold time at a verified pH. Viral filtration needs pre- and post-use integrity. Chromatography resin has a cycle limit. Miss any one of them and the batch record says the product is clean, sterile, and pure, whether or not that is actually true.

Those constraints are enforced by people watching clocks and reading gauges, and the record of whether they held is the operator's signature on a form. If a clock is missed or a gauge misread, nobody finds out until QA reviews the form, often after the next step has already started.

Labbit enforces hold times and pH windows with automatic deviation on excursion, binds filter integrity results to the batch, counts resin cycles per lot against the validated limit, and tracks diavolumes and final concentration through UF/DF.

‍

PRE-CONFIGURED WORKFLOWS

Workflows out of the box

Built visually in BPMN, adapted to your lab, and changed without a vendor release.

Protein A Capture; Polishing Chromatography; Low pH Viral Inactivation; Viral Filtration; Ultrafiltration / Diafiltration; Bulk Drug Substance Fill & Freeze; Chromatography Resin & Membrane Lifecycle
Targeted Amplicon Sequencing

Instruments and platforms

Instruments and platforms

Cytiva AKTA ready and AKTA process; Repligen OPUS columns and KrosFlo TFF; Asahi Planova; Merck Viresolve and Pellicon; Sartorius Celsius
This is some text inside of a div block.

FAQ

Frequently Asked Questions

Does Labbit enforce viral inactivation hold time and pH?

+
-

Yes. Hold time and pH windows are enforced in the workflow, and out-of-window events open a deviation automatically.

Is chromatography resin lifecycle tracked?

+
-

Yes. Cycle counting per resin lot against validated limits, with cleaning verification and storage tracking across campaigns

Are filter integrity results captured?

+
-

Yes. Pre- and post-use integrity for Planova and Viresolve filters bind to the batch with flux decay monitoring.

Does Labbit integrate with AKTA systems?

+
-

Yes. Cytiva AKTA ready and process systems integrate for run capture and eluate pool decisions in the record.

+
-

SEE IT ON YOUR ASSAYS

See your workflow running in Labbit

Bring an assay your team runs today. We’ll show you how it’s configured, executed, and reviewed.